'Deep intubation of the GuideLiner catheter within a soft 6-F guide provides better backup support and is less traumatic than using stiff 7- and 8-F guides that were previously required in. newer technologies such as the GuideLiner catheter (Vascular Solutions. In Europe, the GuideLiner received CE Mark clearance and was launched in October. In patients undergoing PCI, the use of 6F guide catheters has been associated. Procedural success rate was high and there were no major complications. Vascular Solutions will launch the device in the United States this month. GL-use resulted in increased back-up and guide catheter alignment for stent delivery in unfavourable tortuous coronary anatomies and complex, heavily calcified, and often distally located lesions, which otherwise may have been considered unsuitable for PCI. As a mother and child system, the GuideLiner catheter (Vascular Solutions Inc. There were no major complications and two minor complications managed without clinical sequelae: one air embolism and one stent dislodgement. Marlins Medico - Offering Guide Liner V3 Catheter, Size: Large at Rs. Indications were to increase back-up of the guide and facilitate stent delivery (59% 41/70), achievement of coaxial alignment of the guide catheter (29% 20/70), and selective contrast injections (13% 9/70). The GL was mainly used for PCI of complex coronary lesions: 97% (68/70) had American Heart Association/American College of Cardiology (AHA/ACC) lesion types B2/C 53% (37/70) were distally located and 23% (17/70) were heavily calcified. To alternately manipulate the GuideLiner catheters, back and forth with seesaw-like motion enabled us to minimize the interruption of balloon tamponade. We prospectively recorded patient and procedural details, technical success, and in-hospital outcome of 65 consecutive patients undergoing "5-in-6" Fr GL-facilitated PCI of 70 target vessels. Guideliner catheter (Vascular Solutions, Minneapolis, MN) is a novel, rapid exchange system which allows deep intubation and facilitate equipment delivery. Two sets of the GC with GuideLiner catheter facilitated us to simultaneously perform temporary hemostasis with balloon tamponade and rapid delivery of a covered stent. We aimed to assess feasibility and safety of GL-use in routine clinical practice. Therefore, we aim to report the indications, success, and efficacy of GuideLiner use in treating complex lesion subset in the present study. There is paucity of data about the efficacy of this device in complex PCI. Minneapolis, MN) is a rapid exchange guide catheter extension system. The GuideLinerâ„¢ (GL) (Vascular Solutions Inc., Minneapolis, MN, USA) is a guide catheter extension system that provides active back-up support by deep coronary intubation. The GuideLiner catheter (Vascular Solutions, Inc. We report a case of angina having a lesion in the left anterior descending artery of a single coronary trunk arising from the ascending aorta. Optimal ostial seating and adequate back-up of guide catheters are required for challenging percutaneous coronary interventions (PCI). The GuideLiner catheter, which is a coaxial guide extension having the advantage of rapid exchange, facilitates coronary intervention for complex lesions.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |